Replacement DuPont FilmTec BW30-400 Element for High-Rejection Industrial Duty
Replacement DuPont FilmTec BW30-400 Element for High-Rejection Industrial Duty

Replacement DuPont FilmTec BW30-400 Element for High-Rejection Industrial Duty

Introduction:Eight-inch brackish elements in the four-hundred-square-foot class are the workhorse of industrial water treatment, and the BW30-400 envelope is the one most plants have standardized on. When that element reaches the end of its life, the question is rarely whether an equivalent exists — it is whether the replacement matches the dimensional envelope, the flow and rejection class, and the pressure and cleaning envelope the plant was built around. This article describes a spiral-wound compatible replacement for that envelope, covering construction, working principle, typical specifications, advantages in continuous industrial duty, application scenarios, compatibility and trademark notes, selection criteria and the commissioning discipline that keeps a replacement performing like the element it replaced.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

Product Introduction

The element is an eight-inch × forty-inch spiral-wound composite polyamide membrane in the 400-square-foot class, built as an independent replacement for the BW30-400 dimensional and duty envelope. It fits standard 8040 pressure vessels, standard brine seals and standard interconnectors, which means a plant does not have to change its racks, pumps or piping to use it. The polishing stage ahead of the rack sits in a water filter housing sized for the plant's existing cartridge arrangement, and a self-cleaning filter upstream protects that stage from the periodic silt slugs that industrial surface supplies deliver after rain.


Working Principle

Feed water is pressurised along the feed channel, passes the feed spacer, and crosses the polyamide layer, which rejects dissolved salts while permeate travels along the permeate carrier toward the central tube. Three properties decide whether a replacement behaves like the original in this duty. First, the envelope must match: a 400-square-foot element produces its rated flow at its rated pressure, and substituting a lower-area element silently derates the train. Second, rejection is a class, not a single number: 99.5 percent stabilized rejection is measured under defined test conditions, and a plant that expects that number at half the test pressure will not get it. Third, the differential pressure budget matters as much as the flow: a replacement with a different spacer thickness changes the pressure drop across the vessel and with it the cleaning interval.

Replacement DuPont FilmTec BW30-400 Element for High-Rejection Industrial Duty


Typical Specifications

Parameter8040 Element (400 ft² class)
Dimensions8.0 in × 40 in
Active membrane area400 ft² (37 m²)
Nominal permeate flow10,500 GPD (40 m³/d)
Stabilized salt rejection99.5%
Minimum salt rejection99.0%
Test condition reference2,000 mg/L NaCl, 225 psi, 25 °C, pH 8, 15% recovery
Feed channel spacer28 mil (0.71 mm)
Maximum feed pressure600 psi (4.1 MPa)
Maximum pressure drop per element15 psi (0.1 MPa)
Maximum pressure drop per vessel50 psi (0.35 MPa)
Feed TDS range500–10,000 mg/L
Operating pH range2–11
Cleaning pH range1–12 (short term)
Maximum feed temperature45 °C
Maximum feed SDI5.0
Free chlorine tolerance< 0.1 ppm
Typical service life2–3 years

Confirm the pressure rating against the vessel and pump the plant already runs; class compatibility does not automatically mean pressure compatibility in every retrofit.


Core Advantages

Drop-in dimensional fit. Standard 8040 envelope, seals and interconnectors.

Matched flow and rejection class. Sized to the 400-square-foot duty rather than below it.

Industrial pressure tolerance. Rated to 600 psi for continuous high-rejection service.

Broad cleaning window. Compatible with acid and alkaline cleaning across pH 1 to 12 short term.

Independent supply. Available without original-brand lead times or pricing.


Application Scenarios

Typical installations serve industrial boiler and process make-up, pharmaceutical and food ingredient water, semiconductor and electronics support loops, metal finishing rinse recovery, and general brackish-water plants where this element class is already the standard.

Replacement DuPont FilmTec BW30-400 Element for High-Rejection Industrial Duty


Competitive Position and Replacement Notes

This element is an independent compatible replacement for the DuPont FilmTec BW30-400 element class. DuPont and FilmTec are trademarks of their respective owners, and BW30-400 is a model designation of that owner. The names appear here only to describe dimensional, flow and duty compatibility. There is no affiliation, endorsement, certification or original-equipment supply relationship, and LEFILTER does not supply original-brand elements. Any plant considering a replacement should verify the envelope, pressure rating and water quality against its own design documents rather than relying on a compatibility statement alone.


Selection Guide

Confirm vessel count, element count per vessel and the existing element's rated flow before ordering.

Match the 400-square-foot area class; do not substitute a smaller element to save cost.

Check the plant's actual maximum feed pressure against the element rating, not the test pressure.

Verify feed SDI and pre-treatment performance, since replacement elements inherit whatever the pre-treatment allows.

Confirm spacer thickness against the plant's fouling history and differential pressure budget.

Decide whether to replace the whole vessel set; mixing old and new elements in one vessel shifts the load onto the new ones.


Installation and Maintenance Notes

Replace vessel sets rather than single elements where possible, and record each vessel's flow, pressure and conductivity separately after start-up so the new elements are not judged against a blended average. Lubricate seals with glycerin, not petroleum grease, and seat the brine seal on the upstream end. Commission at the plant's normal recovery and compare against the previous element's last clean performance, not its performance when fouled. Keep differential pressure below the vessel limit, clean on a fifteen-percent normalized flow decline rather than on a calendar, and log cleaning efficacy so the next replacement interval is planned rather than discovered.


FAQ

Q1. Is this the same element as the original brand?

A1: No. It is an independent compatible replacement built to the same dimensional and duty envelope; it is not an original-brand product.

Q2. Can it be mixed with existing elements in the same vessel?

A2: It can physically, but the new element will carry more flux and foul faster. Replace sets where the budget allows.

Q3. Will the flow be identical out of the box?

A3: Within the class, yes, subject to the same temperature, pressure and feed conditions under which both were rated.

Q4. What pressure does the plant need?

A4: Whatever its design documents specify; the element's rating is a limit, not an operating target.

Q5. Does using a compatible element affect warranty on the vessel or pump?

A5: That is a question for the vessel and pump suppliers; the element itself carries its own supply warranty.


Related Products

BW30FR-400/34 Water Treatment RO Reverse Osmosis Membrane

40-inch RO membrane water purifier membrane

High Efficiency Reverse Osmosis Membrane for Water Treatment

Commercial Reverse Osmosis Membrane for Pure Water System

High Salt Rejection RO Membrane for Brackish Water Treatment

Please fill in your procurement needs and contact information

whatsapp