
RO Membrane for Post-Coagulation Water with Residual Aluminium and Polymer
Introduction:Coagulation is supposed to end at the clarifier. In practice a fraction of the aluminium and a fraction of the polymer carry through, and both of them end up on the membrane surface. Aluminium forms a gelatinous hydroxide layer that is invisible in turbidity readings; polymer binds that layer to the membrane and makes it harder to remove. A membrane fed from post-coagulation water therefore needs a pretreatment check rather than a bigger pump, and its cleaning programme has to address both an acid-soluble and an alkaline-soluble deposit. This article covers a spiral-wound element for post-coagulation water with residual aluminium and polymer, including construction, working principle, typical specifications, advantages in this duty, application scenarios, compatibility notes, selection criteria and the dosing discipline that keeps coagulant out of the element.
We're here to help:
Easy ways to get the answers you need.
Product parameter:
Product Introduction
The element is a four-inch or eight-inch spiral-wound composite polyamide membrane fed with settled water from a coagulation and sedimentation stage. The feed has already passed coagulation, flocculation and clarification, and may pass media filtration before the membrane; the chemistry that remains, not the solids, is what the element has to tolerate. The polishing stage ahead of the element sits in a water filter housing chosen for a feed that looks clear but carries dissolved coagulant residue, while a self-cleaning filter protects that stage from the floc that escapes whenever the clarifier is upset.
Working Principle
Feed water is pressurised along the feed channel and crosses the polyamide layer, which rejects the salts the process targets. Three points define the duty. First, residual aluminium is a coagulant problem, not a membrane problem: over-dosing or poor mixing leaves aluminium that precipitates as hydroxide on the membrane, and the fix belongs in the coagulation stage. Second, polymer turns a soft deposit into a sticky one: the polymer binds the hydroxide layer and the organic matter together, so a deposit that would have rinsed off instead has to be chemically dissolved. Third, the two deposits need opposite chemistries: aluminium hydroxide responds to acid, polymer and organic matter respond to alkaline detergent, and a plant that only ever runs one of the two will watch the other accumulate.

Typical Specifications
| Parameter | 4040 Element | 8040 Element |
|---|---|---|
| Dimensions | 4.0 in × 40 in | 8.0 in × 40 in |
| Active membrane area | 85 ft² (7.9 m²) | 400 ft² (37 m²) |
| Nominal permeate flow | 2,400 GPD (9.1 m³/d) | 10,500 GPD (40 m³/d) |
| Stabilized salt rejection | 99.0% | 99.5% |
| Feed channel spacer | 34 mil (0.86 mm) | 34 mil (0.86 mm) |
| Maximum feed pressure | 600 psi (4.1 MPa) | 600 psi (4.1 MPa) |
| Typical operating pressure | 150–300 psi (1.0–2.1 MPa) | 200–350 psi (1.4–2.4 MPa) |
| Feed TDS range | 300–4,000 mg/L | 300–4,000 mg/L |
| Feed turbidity after pretreatment | < 1 NTU | < 1 NTU |
| Residual aluminium (target) | < 0.05 mg/L | < 0.05 mg/L |
| Residual polymer (target) | below detectable carryover | below detectable carryover |
| Maximum feed temperature | 45 °C | 45 °C |
| Operating pH range | 3–11 | 3–11 |
| Recovery | 60–75% | 65–80% |
| Free chlorine tolerance | < 0.1 ppm | < 0.1 ppm |
| Typical service life | 2–3 years with controlled dosing | 2–3 years with controlled dosing |
The residual aluminium figure is a design target, not a tolerance: it is the number the coagulation stage should be tuned to deliver.
Core Advantages
Handles a clear but chemically loaded feed. Works where turbidity says clean and chemistry says otherwise.
Wide channel for floc excursions. The 34 mil spacer absorbs the deposits a clarifier upset produces.
Cleanable from both directions. Acid and alkaline washes each address one of the two fouling types.
Stable output across dosing changes. Performance holds as coagulant dose is trimmed toward the target.
Standard envelope. Fits existing 4040 and 8040 housings in municipal and industrial plants.
Application Scenarios
Typical installations serve municipal plants adding membrane polishing after conventional coagulation, industrial plants treating river or reservoir water with alum or PAC, surface-water systems with polymer-assisted clarification, and plants retrofitting RO onto an existing clarifier.

Competitive Position and Replacement Notes
This element is an independent compatible replacement for 4040 and 8040 elements in the low-pressure and brackish ranges commonly supplied by DuPont FilmTec, Hydranautics, Toray and Koch. All brand and model names are trademarks of their respective owners and appear only to describe dimensional and duty compatibility; no affiliation, endorsement or original-equipment supply is implied. LEFILTER does not supply original-brand elements.
Post-coagulation projects are decided by coagulant dosing control and clarifier stability, not by element brand. An element behind an over-dosed clarifier fouls on schedule, whoever made it.
Selection Guide
Measure residual aluminium and residual polymer at the clarifier outlet, not just turbidity.
Tune coagulant dose and mixing energy to hold aluminium below the target before adding membrane capacity.
Provide media filtration or UF between clarifier and element, and verify its performance on upset conditions.
Confirm both acid and alkaline cleaning are available, since the deposit is mixed.
Watch the clarifier's sludge blanket, because carryover is the usual trigger for rapid fouling.
Set cleaning triggers on normalized flow and differential pressure, not on a calendar.
Installation and Maintenance Notes
Install with the brine seal toward the feed and commission on settled water at steady dose, recording pressure, flow and turbidity at start-up. Track residual aluminium weekly and correlate it with any pressure rise; a jump in both usually means the coagulant dose drifted. Clean with a low-pH wash for the hydroxide layer and an alkaline wash for polymer and organics, and inspect the element face after each clean to see which deposit is winning. Keep the clarifier sludge removal on schedule, change cartridges on differential pressure, and verify the self-cleaning filter after any clarifier upset.
FAQ
Q1. Why does residual aluminium matter if turbidity is low?
A1: Because aluminium hydroxide is gelatinous and largely invisible in turbidity, yet it deposits on the membrane surface.
Q2. Does polymer make cleaning harder?
A2: Yes. It binds the hydroxide and organic layers together, so both chemistries become necessary rather than either one alone.
Q3. Which wash comes first?
A3: Alkaline first for organics and polymer, acid second for the hydroxide and any mineral scale, with the order adjusted to what the inspection shows.
Q4. Can the element tolerate an occasional clarifier upset?
A4: Occasionally, with cleaning afterwards. Repeated carryover shortens life regardless of element quality.
Q5. Does this element replace an original-brand part?
A5: It is an independent compatible replacement matched by envelope and duty class; brand names describe compatibility only.
Related Products
BW30FR-400/34 Water Treatment RO Reverse Osmosis Membrane
40-inch RO membrane water purifier membrane
High Efficiency Reverse Osmosis Membrane for Water Treatment
Commercial Reverse Osmosis Membrane for Pure Water System
High Salt Rejection RO Membrane for Brackish Water Treatment
Please fill in your procurement needs and contact information








