RO Membrane for Arsenic and Radium Bearing Groundwater
RO Membrane for Arsenic and Radium Bearing Groundwater

RO Membrane for Arsenic and Radium Bearing Groundwater

Introduction:Arsenic and radium behave differently in water treatment, but they arrive from the same place: reducing conditions in an aquifer, where iron and manganese are also dissolved and where the raw water often looks perfectly clear. Arsenic needs oxidation before it can be filtered at all; radium is removed by softening or by co-precipitation with barium sulfate; and RO sits at the end of the train to catch what remains and to strip the salinity that comes with it. This article covers a spiral-wound element for arsenic and radium bearing groundwater, including construction, working principle, typical specifications, advantages in this duty, application scenarios, compatibility notes, selection criteria and the maintenance discipline a small plant needs.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

Product Introduction

The element is a four-inch or eight-inch spiral-wound composite polyamide membrane used as the final treatment stage after oxidation, co-precipitation and media filtration. Well water is oxidised to convert arsenite to arsenate, dosed for co-precipitation, filtered through media beds, softened where radium and hardness require it, and only then passed to the membrane. The polishing cartridges ahead of the element sit in a water filter housing sized for the low solids load this duty produces, while a self-cleaning filter protects that stage from the filter bed fines and iron floc that a backwash cycle can carry downstream.


Working Principle

Feed water is pressurised along the feed channel and crosses the polyamide layer. Both arsenate and radium are rejected effectively — radium as a divalent cation, arsenic as a dissolved species that the membrane barrier holds back. Two points govern the design. First, oxidation is the true treatment step: arsenite is far harder to remove than arsenate, so the oxidation stage ahead of the membrane decides whether arsenic removal works at all. Second, the concentrate is where the risk moves to: arsenic, radium and any co-precipitation sludge residue concentrate into a small reject stream that must be managed as a radioactive or hazardous waste stream depending on the radium activity, not disposed of casually.

RO Membrane for Arsenic and Radium Bearing Groundwater


Typical Specifications

Parameter4040 Element8040 Element
Dimensions4.0 in × 40 in8.0 in × 40 in
Active membrane area85 ft² (7.9 m²)400 ft² (37 m²)
Nominal permeate flow2,400 GPD (9.1 m³/d)10,500 GPD (40 m³/d)
Stabilized salt rejection99.0%99.5%
Arsenic rejectiontypically > 95% (as arsenate)typically > 95% (as arsenate)
Radium rejectiontypically > 95%typically > 95%
Feed channel spacer34 mil (0.86 mm)34 mil (0.86 mm)
Maximum feed pressure600 psi (4.1 MPa)600 psi (4.1 MPa)
Typical operating pressure150–250 psi (1.0–1.7 MPa)200–300 psi (1.4–2.1 MPa)
Feed TDS range500–5,000 mg/L500–5,000 mg/L
Maximum feed temperature45 °C45 °C
Operating pH range3–113–11
Recovery55–75%60–80%
Free chlorine tolerance< 0.1 ppm< 0.1 ppm
Typical service life2–3 years2–3 years

Arsenic rejection figures assume adequate pre-oxidation; without it, removal falls sharply.


Core Advantages

Removes both contaminants. One barrier covers arsenic and radium together with the salinity that accompanies them.

Works after conventional stages. Fits downstream of oxidation and media filtration rather than replacing them.

Stable permeate. Consistent low-arsenic output makes blending and compliance monitoring straightforward.

Handles iron and manganese residue. The wide channel tolerates the fines that oxidation trains release.

Compact for small plants. Fits community water stations with limited floor area.


Application Scenarios

Typical installations serve community and small municipal wells where arsenic exceeds the limit, sites with naturally occurring radium in sandstone and granite aquifers, mining-affected groundwater, and rural schools or clinics drawing from a single contaminated borehole.


Competitive Position and Replacement Notes

This element is an independent compatible replacement for 4040 and 8040 elements in the low-pressure and brackish ranges commonly supplied by DuPont FilmTec, Hydranautics, Toray and LG Chem. All brand and model names are trademarks of their respective owners and appear only to describe dimensional and duty compatibility; no affiliation, endorsement or original-equipment supply is implied. LEFILTER does not supply original-brand elements.

Arsenic and radium projects are decided by the waste route and by oxidation control, not by element brand. A plant without a licensed concentrate disposal path is not a plant, whatever membrane is inside it.


Selection Guide

Speciate arsenic — arsenite versus arsenate — and measure iron, manganese, sulfate and radium activity.

Confirm the oxidation and co-precipitation stages are designed before the membrane is sized.

Verify the concentrate route and its regulatory classification before ordering equipment.

Size for peak demand and provide duty and standby capacity for a community supply.

Check that pretreatment reliably holds turbidity below the element's limit, since iron floc will foul quickly.

Plan arsenic and radium monitoring at both feed and permeate, not permeate alone.


Installation and Maintenance Notes

Install with the brine seal toward the feed and lubricate O-rings with clean water only. Commission with a flush to drain and verify arsenic and radium in the first permeate samples before release. Log pressures, flows and permeate arsenic weekly. Clean with an alkaline detergent for iron and organic fouling, and keep cleaning chemicals out of the concentrate handling system's documentation trail. Replace cartridges on a fixed interval and check the self-cleaning filter's backwash. Handle spent cartridges and any filter media as the waste classification requires.


FAQ

Q1. Can RO remove arsenic on its own?

A1: It removes arsenate well but arsenite poorly. Oxidation ahead of the membrane is the step that makes removal reliable.

Q2. Why is softening included before RO?

A2: It removes hardness and, in many cases, radium, which reduces scaling and takes load off the membrane.

Q3. What happens to the arsenic and radium removed?

A3: They concentrate in the reject stream, which is normally managed as a regulated waste. The disposal route must be approved before the plant operates.

Q4. Is radium a health risk in the permeate?

A4: Not when rejection and integrity are verified; monitoring at commissioning and periodically afterwards is the safeguard.

Q5. Does this element replace an original-brand part?

A5: It is an independent compatible replacement matched by envelope and duty class; brand names describe compatibility only.


Related Products

BW30FR-400/34 Water Treatment RO Reverse Osmosis Membrane

40-inch RO membrane water purifier membrane

High Efficiency Reverse Osmosis Membrane for Water Treatment

Commercial Reverse Osmosis Membrane for Pure Water System

High Salt Rejection RO Membrane for Brackish Water Treatment

Please fill in your procurement needs and contact information

whatsapp