RO Membrane for Leather Tanning and Finishing Effluent Reuse
RO Membrane for Leather Tanning and Finishing Effluent Reuse

RO Membrane for Leather Tanning and Finishing Effluent Reuse

Introduction:Tannery effluent is one of the harder streams in industry: high salinity from soaking and pickling, deep colour from vegetable and synthetic tanning agents, sulphide and lime from unhairing, and chrome from tanning. Each of these attacks a membrane in a different way. Reuse is still practical, but only on a stream that has been segregated, equalised and chemically pretreated, and only with an element built for high salt and high colour. This article covers a spiral-wound element for tannery effluent reuse, including construction, working principle, typical specifications, advantages in this duty, application scenarios, compatibility notes, selection criteria, and installation and maintenance practice for tanning and finishing effluent applications.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

Product Introduction

The element is an 8-inch × 40-inch spiral-wound composite polyamide membrane with 400 square feet of area and a wide 34 mil feed channel, selected for a feed that is coloured, saline and prone to organic fouling. As a replacement it matches 8040 envelopes in the low-fouling range by dimension, active area, flow and rejection. Treated effluent passes equalisation, chemical pretreatment and a cartridge stage before the membrane, the cartridges being held in a water filter housing rated for the residual solids in tannery water; where the pretreatment leaves hide fibres, hair and lime sludge fines in the stream, a self-cleaning filter ahead of the cartridges keeps those solids out of the housing and stops them from abrading the element's outer wrap.


Working Principle

Effluent enters the element along the feed channel spacer and crosses the polyamide layer under pressure. Permeate, low in salt and colour, returns to soaking, washing or floor-cleaning duty; concentrate carries the residual salinity and colour to further treatment or disposal. Two mechanisms dominate performance here. First, colour bodies — humic and tannin-derived organics — adsorb onto the membrane and reduce flux even when turbidity is low, so pretreatment must remove them rather than merely filter solids. Second, high salinity raises osmotic pressure, meaning a tannery stream at 3,000–6,000 mg/L TDS needs noticeably more pressure than municipal feed for the same output, and recovery is capped by the scaling risk of the concentrate rather than by the element.

RO Membrane for Leather Tanning and Finishing Effluent Reuse


Typical Specifications

Parameter8040 Element
Dimensions8.0 in × 40 in (201 mm × 1,016 mm)
Active membrane area400 ft² (37 m²)
Nominal permeate flow10,500 GPD (40 m³/d)
Stabilized salt rejection99.5%
Colour removaltypically > 95%
Feed channel spacer34 mil (0.86 mm)
Maximum feed pressure600 psi (4.1 MPa)
Typical operating pressure250–400 psi (1.7–2.8 MPa)
Feed TDS range2,000–6,000 mg/L typical
Maximum feed temperature45 °C
Operating pH range3–11
Cleaning pH range2–12
Maximum feed turbidity1 NTU
Recovery50–70% (scaling-limited)
Free chlorine tolerance< 0.1 ppm
Typical service life2–3 years

Values depend on segregation and pretreatment quality; chrome-bearing streams are usually treated separately rather than combined.


Core Advantages

High salt tolerance. Handles the salinity that makes tannery effluent expensive to discharge.

Colour removal. Permeate is clear enough for washing and cleaning reuse, not just for dilution.

Fouling-tolerant channel. The wider spacer copes with the organic load that survives pretreatment.

Reduced discharge volume. Concentrating the stream cuts the hydraulic load on the plant's treatment system.

Robust cleaning regime. Tolerates the alkaline and acid cleaning cycles that coloured organic fouling requires.


Application Scenarios

Typical installations include beamhouse and tanning effluent reuse in shoe-leather and upholstery tanneries, finishing and dyeing house water recovery, and chrome-free or vegetable tanning lines where process water is recycled into soaking and washing.

RO Membrane for Leather Tanning and Finishing Effluent Reuse


Competitive Position and Replacement Notes

This element is an independent compatible replacement for 8040 elements in the low-fouling and brackish ranges commonly supplied by DuPont FilmTec, Hydranautics, Toray, LG Chem and Koch. All brand and model names are trademarks of their respective owners; they appear here only to describe dimensional and duty compatibility and imply no affiliation, endorsement or original-equipment supply. LEFILTER is not affiliated with these manufacturers and does not supply original-brand elements.

In tanneries, stream segregation decides success more than element choice. Replacing an element on a combined, poorly pretreated stream will foul within days regardless of brand, while the same element on a segregated, pretreated stream performs for years.


Selection Guide

Segregate streams first — chrome, sulphide and finishing effluent should not be combined before treatment.

Characterise TDS, colour, COD, sulphide and chrome content of the stream that will actually feed the RO.

Confirm pretreatment removes colour bodies, not just suspended solids.

Size for the coldest feed temperature and the highest salinity season.

Check concentrate disposal rules; chrome-bearing concentrate is normally handled as hazardous.

Verify cleaning chemical compatibility with the element's pH and temperature limits.


Installation and Maintenance Notes

Install with the brine seal facing the feed, lubricate O-rings with clean water, and seat fully. Flush to drain for at least 30 minutes before returning permeate. Record pressure, differential pressure, permeate flow, conductivity and colour at commissioning. Clean with alkaline detergent for organic and colour fouling and low-pH solution for mineral scale; keep cleaning temperature within limits. Clean when differential pressure rises 10–15%. Replace cartridges on a fixed interval and inspect the self-cleaning filter's backwash cycle weekly.


FAQ

Q1. Can RO handle chrome-bearing effluent?

A1: Only after reduction and precipitation of chrome, and usually as a separate stream. Chrome should not be fed to the membrane.

Q2. Why does colour persist in the permeate?

A2: Colour bodies are low-molecular organics; if pretreatment is inadequate they pass or foul the surface. Permeate colour should be monitored as a fouling indicator.

Q3. Is the permeate suitable for soaking?

A3: Yes for many soaking and washing duties once quality is verified; dyeing and finishing may need tighter limits.

Q4. What recovery is realistic?

A4: Commonly 50–70%, limited by scaling and by concentrate disposal rules rather than by the element.

Q5. Does this element replace an original-brand part?

A5: It is an independent compatible replacement matched by envelope and duty class; brand names are used only to describe compatibility.


Related Products

BW30FR-400/34 Water Treatment RO Reverse Osmosis Membrane

40-inch RO membrane water purifier membrane

High Efficiency Reverse Osmosis Membrane for Water Treatment

Commercial Reverse Osmosis Membrane for Pure Water System

High Salt Rejection RO Membrane for Brackish Water Treatment

Please fill in your procurement needs and contact information

whatsapp