Low Rejection RO Membrane for TDS Reduction in Irrigation Reuse Water
Low Rejection RO Membrane for TDS Reduction in Irrigation Reuse Water

Low Rejection RO Membrane for TDS Reduction in Irrigation Reuse Water

Introduction:Reclaimed water reused for irrigation often needs only partial salinity reduction rather than high-purity permeate, which makes a high-rejection RO system oversized and unnecessarily energy-intensive. A low rejection RO membrane is designed to bring TDS and conductivity down to a target irrigation range while maintaining higher permeate flow at lower operating pressure, suited to treated effluent, agricultural runoff and recycled drainage water. With settled and filtered feed, controlled recovery and scheduled cleaning, the element helps balance salt reduction, water recovery and crop irrigation water quality.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

Product Introduction

LEFILTER low rejection RO membranes are spiral-wound thin-film composite elements configured for partial TDS reduction in irrigation reuse, rather than maximum salt rejection for boiler or drinking-grade water. The range covers standard 4040 and 8040 formats with compatible center tubes, end caps and seals, allowing retrofit into existing pressure vessels and irrigation reuse skids. On a farm or landscape reuse system, the RO stage is protected upstream by a water filter housing holding security cartridges that trap residual particulates, and a self-cleaning filter continuously removes suspended solids, silt and colloidal load before the membrane inlet.

The elements are selected for a balanced rejection-to-flow profile, reliable performance on mildly saline reclaimed water, and cleanability under scheduled CIP. They are positioned as independent compatible replacement elements, not original manufacturer products; referenced brand names are used only to describe fit and performance equivalence.


Working Principle

Low Rejection RO Membrane for TDS Reduction in Irrigation Reuse Water

Settled, filtered and polished reuse water is pressurized into the spiral-wound RO element. Water molecules pass through the semi-permeable membrane leaf and travel along the permeate spacer to the central collection tube, producing permeate with reduced TDS for irrigation. A portion of dissolved salts passes through according to the membrane's lower rejection rating, while the remaining salts and rejected contaminants concentrate into the concentrate stream, which is sent to blending, further treatment or discharge.

The feed spacer maintains turbulent cross-flow to limit settlement of silt and colloids; the permeate spacer guides purified water to the outlet; end-cap seals prevent feed-to-permeate bypass. Because irrigation reuse feed can carry organic matter, surfactants and seasonal load swings, consistent filtration, controlled recovery and periodic cleaning are required to preserve flow and rejection over element life.


Typical Specifications

ItemSpecification
Element format4040 / 8040 spiral-wound
Membrane typeThin-film composite polyamide, low-rejection / partial-desalting series
Target feedFiltered, polished irrigation reuse water, mildly saline reclaimed or runoff water
Permeate flowHigher-flow rating per format, sized to irrigation demand and recovery
RejectionBalanced partial TDS/conductivity reduction; lower salt passage control than high-rejection BWRO
Feed temperature range5–45 °C (continuous operation below design upper limit)
Operating pH range4–10
Cleaning pH range2–11 (with suitable CIP chemicals and thorough rinsing)
Free chlorine tolerance< 0.1 ppm at the membrane inlet; oxidation control upstream required
Seals and hardwareLow-leaching seals where specified; standard center tube and end cap
Typical service life2–3 years with protected pretreatment and regular CIP


Core Advantages

Partial desalting match: 

reduces TDS and conductivity to irrigation target without the over-design of a high-rejection system.

Higher flow, lower pressure: 

balanced rejection-to-flow profile supports irrigation volumes at economical operating pressure.

Reuse-oriented fit: 

suited to reclaimed effluent, runoff and drainage water recycled for field, greenhouse and landscape irrigation.

Cleanable performance: 

broad cleaning pH window supports removal of organic, silt and colloidal fouling.

Drop-in compatibility: 

standard 4040 / 8040 dimensions and connections suit replacement in existing vessels and skids.


Application Scenarios

Low Rejection RO Membrane for TDS Reduction in Irrigation Reuse Water

Agricultural field and crop irrigation with reclaimed or partially saline reuse water.

Greenhouse, nursery and landscape irrigation water TDS reduction.

Blending loops where partial desalination brings reuse water to target salinity.

Farm and municipal reuse schemes sending treated effluent to irrigation after RO polishing.


Competitive Position and Replacement Notes

LEFILTER elements are compatible replacement membranes evaluated against common industrial RO formats from brands such as DuPont FilmTec, Dow, Hydranautics, Toray, Suez and 3M. They are not original-equipment products of those manufacturers; brand references are for cross-reference and fit comparison only. Rejection and permeate salinity depend on feed TDS, temperature, recovery rate, pressure and blending target, and should be validated on-site against the crop irrigation water standard.


Selection Guide

Irrigation target: 

define target EC/TDS and crop tolerance; select low-rejection rating to meet that target without over-treating.

Blending option: 

consider blending RO permeate with untreated reuse water if only modest salt reduction is required.

Feed quality: 

confirm filtration, security cartridges and organic/silt removal; unstable upstream load fouls the membrane rapidly.

Recovery and concentrate: 

size recovery and concentrate disposal to match irrigation return and local discharge rules.

Temperature and oxidation control: 

keep feed within the operating window and remove residual chlorine or oxidants upstream to protect the polyamide sheet.


Installation and Maintenance Notes

Flush and clean new vessels and piping before loading elements; remove construction debris, oil and residual chemicals.

Load elements gently with seal lubrication; avoid dry twisting, pinching or seal damage during insertion.

Start pumps gradually and raise pressure and flow slowly to prevent compaction and hydraulic shock.

Monitor permeate flow, conductivity, differential pressure and recovery trend; schedule CIP when flux drops or pressure rises indicate fouling.

Store spare elements wet in preservative solution within the recommended temperature range; do not allow membrane leaves to dry out.


FAQ

Q1. Is a low rejection membrane the same as a standard high-rejection RO?

A1: No. This series is configured for partial TDS reduction and higher flow, suitable for irrigation reuse; it is not intended for drinking-water, boiler makeup or other high-purity permeate duty.

Q2. How much salt does it remove?

A2: Removal depends on feed TDS, temperature, pressure, recovery and the selected element rating; permeate conductivity should be tested against the crop irrigation target rather than assumed from a generic rejection figure.

Q3. Can it treat raw runoff or untreated wastewater directly?

A3: No. Reuse feed must be settled, filtered and polished, with silt, organic matter and oxidants controlled before reaching the RO stage.

Q4. Are the elements compatible with existing 8040 vessels?

A4: Standard 8040 and 4040 elements use conventional center tubes, end caps and seal arrangement. Confirm vessel inner diameter, connector style and brine seal fit before installation.

Q5. What shortens membrane life in irrigation reuse service?

A5: Poor filtration, silt and organic carryover, seasonal load swings, pH and temperature excursions, residual oxidants, excessive recovery and delayed cleaning all accelerate irreversible performance loss.


Related Products

BW30FR-400/34 Water Treatment RO Reverse Osmosis Membrane

40-inch RO membrane water purifier membrane

High Efficiency Reverse Osmosis Membrane for Water Treatment

Commercial Reverse Osmosis Membrane for Pure Water System

High Salt Rejection RO Membrane for Brackish Water Treatment

Please fill in your procurement needs and contact information

whatsapp