Toray TML10D Low Energy Reverse Osmosis Membrane
Toray TML10D Low Energy Reverse Osmosis Membrane

Toray TML10D Low Energy Reverse Osmosis Membrane

Introduction:The TML10D anti-pollution reverse osmosis membrane, by applying a special substance on the surface of the composite membrane, has improved the charge and smoothness of the membrane surface. At the same time, its structure has shortened the length of the membrane sheet and increased the number of pages of the membrane bag, which can reduce the adsorption of organic substances and microorganisms on the membrane surface, significantly improving the performance of the membrane element under high bio-fouling conditions and the recovery performance after chemical cleaning.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

The TML10D anti-pollution reverse osmosis membrane, by applying a special substance on the surface of the composite membrane, has improved the charge and smoothness of the membrane surface. At the same time, its structure has shortened the length of the membrane sheet and increased the number of pages of the membrane bag, which can reduce the adsorption of organic substances and microorganisms on the membrane surface, significantly improving the performance of the membrane element under high bio-fouling conditions and the recovery performance after chemical cleaning.


image

Key operational points for the Dylon TML10D anti-contamination membrane:

1. Strictly follow the startup procedure to prevent membrane damage caused by excessive shock. Before starting the system and loading the membrane elements, instrument calibration, membrane pre-treatment, and other system checks should be conducted.

2. Always reduce any pressure shock or cross-flow fluctuations on the roll-type elements. During the startup process, it is recommended to make a gradual pressure change from static to operational state.

3. The maximum allowable pressure drop for the entire pressure vessel (membrane housing) is 50 psi (3.4 bar).

4. No static pressure should be generated on the product water side.

5. Always keep the membrane elements moist after the first soaking.

6. If the operation restrictions and guidelines are not followed, the manufacturer will not provide warranty.

7. In the case of long-term system shutdown, it is recommended to immerse the membrane elements in maintenance fluid to prevent bacterial growth.

8. The produced water from the membrane elements for the first hour should be discharged.

9. Users should ensure that chemicals and lubricants do not have any adverse effects on the membrane elements.