RO Membranes 8040/4040 Reverse Osmosis Water Spare Parts for RO System
RO Membranes 8040/4040 Reverse Osmosis Water Spare Parts for RO System

RO Membranes 8040/4040 Reverse Osmosis Water Spare Parts for RO System

Introduction:ULP-8040 / ULP-4040 elements can produce high-quality water at low operating costs. They are ideal for use in large-scale industrial and municipal water treatment systems. ULP-8040 / ULP-4040 elements can lower the operating pressure by 40%.

We're here to help:
Easy ways to get the answers you need.

  • Product parameter
  • Inquiry

Product parameter:

Product Specifications

ModelActive Membrane Area
ft2(m2)
Stabilized Salt Rejection
%
Minimum Salt Rejection
%
Permeate Flow
Rate gpd(m3/d)
ULP-8040400(37)99.399.011,500(44)
ULP-404078(7.2)99.399.02250(8.7)


Test Condition: Feed Water Pressure 1.03MPa (150 psi); Feed Water Temperature 25 °C (77 °F); Feed Water Concentration 2,000 ppm NaCl; Feed Water pH 7; Permeate Recovery 15%.


Dimensions

ModelA inch(mm)B inch(mm)C inch(mm)D inch(mm)
ULP-804040(1,016)01.125(29)7.9(201)
ULP-404040(1,016)1.05(26.7)0.75(19)3.9(99)

Operation Condition
Maximum Operating Pressure 41 bar(600 psi) Maximum Operating Temperature 45ºC(113ºF)
Maximum Pressure Drop per Element 1.0 bar (15 psi)
pH Range, Continuous Operation 2-11 pH Range, Chemical Cleaning 1-13
Maximum Feed Silt Density Index (SDI15) 5.0 Free Chlorine Tolerance < 0.1 ppm
 

Note

  1. Permeate flow rates for individual elements may vary ±15%.

  2. Membrane active areas may vary ±4%.

  3. Stabilized salt rejection is generally achieved after continuous using for 24-48 hours, which depending on feed water qualities and operating conditions.