Ultra-low pressure 4040 8040 reverse osmosis water treatment system ULP 4040
Introduction:The operating pressure is approximately two-thirds of that of conventional composite membranes. This reduces the investment costs of pumps, pipelines, containers and other equipment, as well as the operating costs of reverse osmosis systems, thereby enhancing economic benefits.
We're here to help:
Easy ways to get the answers you need.
Product parameter:
Stable desalination rate: 99%
Average permeation flow rate: 1000 GPD (3.8 cubic meters/day)
Operating pressure and suitable range: Ultra-low pressure operation, suitable for low-concentration brackish water
Test conditions:
Test pressure: 100 psi (0.69 MPa)
Test solution concentration: 1500 ppm NaCl
Recovery rate: 8%
ULP/XULP series membrane elements
The series membrane elements are made of polyamide composite membrane material and achieve the required permeation flow rate and high desalination rate under ultra-low pressure operation conditions.
The operating pressure is approximately two-thirds of that of conventional composite membranes. This reduces the investment costs of pumps, pipelines, containers and other equipment, as well as the operating costs of reverse osmosis systems, thereby enhancing economic benefits.
The series of membrane elements are suitable for desalination of water sources with a salinity level of less than approximately 2000 ppm, including surface water, groundwater, tap water and municipal water. They are mainly used in various industries, such as pure water production, boiler feed water, food processing and pharmaceuticals.
Membrane element test conditions
Test pressure: 150 psi (1.03 MPa) | 100 psi (0.69 MPa)
Test solution temperature: 25 °C
Test solution concentration: 1500 ppm
Test solution pH: 7.5
Single membrane element recovery rate:
15% for models 8040, 4040, 2540
8% for models 4021, 2521
The maximum operating conditions of this membrane element:
Maximum working pressure: 600 psi (4.14 MPa)
Maximum feed flow rate:
75 GPM (17 cubic meters/hour) for the 8040 model
16 GPM (3.6 cubic meters/hour) suitable for the 4040, 4021 models
6 GPM (1.4 cubic meters/hour) suitable for the 2540, 2521 models
Maximum pressure drop per element:
15 psi (0.1 MPa) for the 8040, 4040, 2540 models
10 psi (0.07 MPa) for the 4021, 2521 models
Maximum feed water temperature: 45 °C
Maximum feed water salinity: 2000 ppm
Maximum feed water hardness (e.g. CaCO3): 60 ppm
Maximum feed water turbidity (NTU): 1
Maximum feed water SDI: 5
Maximum feed water COD: 10 ppm
Maximum feed water BOD: 5 ppm
Feed water free chlorine concentration: < 0.1 ppm
pH range: 2 to 12
Storage temperature of membrane elements: 5 °C to 45 °C