Lefilter2025-07-30 BACK TO LIST
Process water is critical for industrial equipment and product manufacturing, yet poor water quality often causes unexpected filtration failures. When filter cartridges clog prematurely or underperform, the culprit may not be the filter itself - but contaminated process water carrying particulate loads that sabotage your operations.
Iron and sediment residues on unfiltered cartridge components below.
As the universal contact medium in cleaning and rinsing operations, process water introduces its own particulate burden throughout production cycles. Beverage industries primarily use two sources:
Tap Water (Potable):
Regulated by Drinking Water Ordinances
Must contain <100 CFU/ml microorganisms
Zero pathogens (E. coli, enterococci)
Well/Spring Water:
Same microbiological standards as tap water
Additional requirement: No sulfite-reducing anaerobes in 50ml samples
Both sources can contain:
Particulates (rust, lime, sand)
Colloidal contaminants
Microbial contaminants (bacteria, yeast, mold)
Heavy sediment and iron deposits on filter cartridges
Modern solutions have evolved from gravel/sand bed filters to advanced systems:
Technology | Advantages |
---|---|
Membrane Cartridges | - Pre-use integrity testing |
Depth Filter Cartridges | - Graded pore structure |
Layered funnel design maximizes particle retention in pre-filters
Asymmetric pore distribution optimizes flow in membrane cartridges
Analysis of 7 wineries revealed diverse approaches to process water filtration:
Winery | Pre-Filter | Membrane Filter |
---|---|---|
I | None | None |
II | 0.3μm depth | None |
III | None | 0.45μm |
IV | 0.3μm depth | 0.2μm |
V | 30μm depth | None |
VI | 1.0μm depth | None |
VII | 0.2μm depth | None |
Testing Methodology:
5L water samples filtered through 0.45μm test membranes
Constant pressure: 1.0 bar (14.5 psi)
Flow rates measured at 200ml and 5L intervals
Visual residue analysis + Ferri-Ferro iron testing
Key Findings:
Winery I (Unfiltered Water):
Easy filtration (end flux >400 ml/min)
Heavy sediment layer on test membrane
Positive iron test indicating pipe corrosion
Winery II (0.3μm Pre-filter):
Initial difficulty (end flux: 296 ml/min)
Post-filtration improvement (end flux: 510 ml/min)
Reduced bacteria/yeast counts
Winery III (0.45μm Membrane Only):
Silica sol concentration limiting flow
No visible residue but flow capped at 400 ml/min
Winery IV (0.3μm + 0.2μm System):
Optimal performance (end flux: 487 ml/min)
Zero residue/microbial contamination
Mandatory Pre-Filtration:
Install depth filters (0.3-1.0μm) for particulate removal
Corrosion Monitoring:
Conduct quarterly Ferri-Ferro tests
Microbial Control:
Supplement with 0.2μm membranes for critical applications
Flow Optimization:
Target end flux >400 ml/min through proper staging
"Filter cartridges don't fail - filtration systems do. Optimizing process water quality is the foundation of reliable industrial operations."
Send Your Inquiry