Specification Matching:
Select filters compatible with pipeline dimensions. If flow capacity is insufficient, install multiple filters in parallel or use bypass filtration.
Optimal Placement:
Install near the pressure source to avoid low inlet pressure. Prioritize proximity to protected system components.
Piping Configuration:
Install in series with main pipelines. Include a bypass line with shutoff ball valves (inlet/outlet/bypass) for uninterrupted supply during maintenance. Add a check valve at the outlet if backflow risks exist.
Temperature Limits:
Ensure fluid temperature does not exceed the filter’s rated tolerance.
Power & Drainage:
Provide 380V three-phase AC power (three-phase, four-wire). Limit drain pipe length to ≤5 meters to prevent backpressure.
System-Specific Considerations:
DC systems: Prioritize precision, pretreatment, and pressure control.
Intermittent systems: Avoid timer-controlled models.
Environmental Protection:
Ensure installation sites are dry, waterproof, and moisture-resistant.
Before seasonal/offline periods, inject corrosion inhibitors into the system and maintain wet layup protection to minimize corrosion.
Pre-Start Checks:
Confirm filter is in ready state.
Inspect all connections for tightness.
Ensure electrical control box is dry.
Power-Up:
Connect power; a green indicator confirms operational readiness.
Critical Notes:
Maintain dry hands when handling electrical components.
Prevent water ingress into the control box during operation.
The system is factory-calibrated. Adjust parameters (manual/auto modes) only if operational needs deviate from default settings.